Modular Adult Airway Simulator Enables Reliable Ultrasound Detection of
Researchers have engineered and evaluated a modular adult simulation platform that integrates front-of-neck airway ultrasound with cardiopulmonary resuscitation mannequins to train clinicians in identifying fatal endotracheal tube misplacements into the esopha
Illustrative imageResearchers have engineered and evaluated a modular adult simulation platform that integrates front-of-neck airway ultrasound with cardiopulmonary resuscitation mannequins to train clinicians in identifying fatal endotracheal tube misplacements into the esophagus. Described in the International Journal of Emergency Medicine, the prototype training system combines an anatomically configured gelatine-based ultrasound phantom, a modified airway management trainer, a resuscitation torso, and a standardized video interpretation assessment module. The system was developed to address a critical gap in adult emergency airway education, where clinicians must rapidly confirm correct tracheal tube placement under high-stress conditions. In initial validation testing, six clinical resuscitation experts evaluated the mechanical integration and procedural realism of the hardware during twenty-eight advanced life support simulation scenarios, while a blinded cohort of nineteen novice learners assessed twenty randomized ultrasound video sequences derived from both human patients and the synthetic phantom. The investigation demonstrated that the low-cost modular simulator could be seamlessly embedded into complex resuscitation workflows without causing technical delays, providing realistic acoustic feedback that enabled trainees to distinguish between correct tracheal intubation and esophageal tube malposition with high overall diagnostic reliability.
The clinical impetus for the novel simulator system centers on the lethal danger of unrecognized esophageal intubation during emergency airway management. In emergent interventions involving unfasted patients, securing the trachea is a high-risk procedure where tube misplacement into the esophagus can prove fatal if undetected. The study authors highlight that unrecognized misplacement continues to occur in emergency intubations, even when providers use video laryngoscopes. Prehospital data from the Netherlands in 2022 showed that twenty percent of cardiac arrest patients had unrecognized esophageal tube placement despite the presence of capnography. Although waveform capnography represents the diagnostic gold standard for tube verification, its signals can appear atypical, attenuated, and difficult to interpret during cardiac arrest or hemodynamic shock due to poor pulmonary perfusion. Moreover, manual bag-mask ventilation in an undetected esophageal intubation causes detrimental gastric insufflation. Front-of-neck point-of-care ultrasound has gained guideline recognition as an alternative method capable of verifying tube position within five seconds without prior positive-pressure ventilation.
To replicate anterior neck sonoanatomy economically, the authors synthesized a reusable ultrasound phantom using precisely measured materials. The recipe required two hundred and fifty grams of Ballistic 3 Type A ballistic gelatine from Gelita, which was combined with seven hundred and fifty milliliters of distilled water and allowed to swell for ten minutes. For preservation and structural durability, three hundred and fifty grams of ninety-nine point nine percent isopropanol from Nanoprotect GmbH and three hundred and fifty grams of ninety-nine point five percent glycerine from WHC GmbH were added. The mass was heated to a maximum of fifty to sixty degrees Celsius and stirred carefully to prevent bubble formation until completely liquid and transparent. To establish realistic acoustic scattering and tissue-like echogenicity on ultrasound, ninety grams of pure cornstarch from ja! were dissolved in distilled water and incorporated into the smooth gelatine mixture. Finally, four teaspoons of food colouring from Dr. Oetker were stirred in to provide complete optical opacity.
The physical casting of airway and esophageal passages relied on modified ten-milliliter plastic syringe barrels. Investigators retracted the plungers of two syringes, severed the distal tips of the barrels, and reinserted the plungers inverted. One syringe was filled with water and placed upright in a plastic mold, where two-thirds of the gelatine admixture was poured around it before hardening in a refrigerator for at least eight hours. A second water-filled syringe was then positioned atop the solid base, covered with the remaining reheated gelatine mixture, and chilled for another eight-hour cycle. Once solidified, the syringes were extracted, leaving internal anatomical lumens. A slot was incised into the false esophagus using a long knife to facilitate tube insertion. The finished phantom was joined with a Laerdal airway management trainer that had been sawed off at the neck, connecting the tracts using a cut twenty-five-centimeter breathing circuit tube and affixing a Practi-Man Plus torso.
The investigation distinguished between two clinical airway examination modalities: type-one post-intubation exams to verify tube placement in an already intubated subject, and type-two peri-intubation exams providing continuous real-time observation during tube passage. To support distinct educational objectives, the researchers engineered adaptable phantom configurations. For static type-one training, two phantoms can be deployed interchangeably: one containing two syringe placeholders to exhibit esophageal malposition, and another with a single syringe placeholder depicting tracheal intubation. For dynamic type-two scenarios, the gelatine wears down mechanically after roughly twenty-five intubations. To overcome this limitation, the team devised a reversible four-syringe phantom usable from both sides, effectively doubling its procedural lifespan. Throughout the experimental period, the gelatine formulation exhibited excellent material resilience, preserving structural integrity without refrigeration and resisting visible deterioration or mold formation. Furthermore, the assembled simulator maintained portable dimensions comparable to conventional resuscitation equipment, ensuring practical setup without introducing undue operational burden.
Usability, mechanical stability, and scenario immersiveness were evaluated across twenty-eight advanced life support simulations by six clinical experts. Following written consent, the experts completed an anonymous four-item survey on a five-point Likert scale ranging from one for strongly disagree to five for strongly agree. Overall agreement regarding the integration of point-of-care ultrasound into resuscitation scenarios reached a mean score of 4.5 out of 5 with a standard deviation of 0.548. Expert ratings for handling, timing, teamwork, and spatial conditions similarly averaged 4.5 with a standard deviation of 0.548. Sonographic imaging realism was scored at a mean of 4.2 with a standard deviation of 0.408, while the transferability of the simulator experience to anticipated real-world resuscitation events received the highest average score of 4.8 with a standard deviation of 0.408. Notably, rapid resetting and replacement of the ultrasound phantom occurred within minutes between training runs, without causing technical failures or instructional distractions.
To evaluate visual perception and image interpretation, nineteen novice learners underwent a blinded software assessment comparing phantom and human sonograms. Before testing, participants received a twenty-minute didactic lecture covering neck sonoanatomy and type-one airway ultrasound fundamentals, followed by thirty minutes of hands-on practice scanning the anterior neck of awake human volunteers without tubes. Trainees then completed a guided pre-test featuring synchronized videos of transducer handling alongside clips illustrating tracheal and esophageal tube positions in both human and phantom models. For the formal examination, learners evaluated twenty randomized video clips shown for five to ten seconds each, without being told whether recordings originated from phantoms or living humans. On an anonymous paper form, participants checked within five seconds whether the sonogram displayed a tracheal single tract or an esophageal double tract position, while rating the perceived quality of each sonogram on an eleven-point Likert scale spanning from zero for poor to ten for best.
The test library contained twenty distinct ultrasound clips acquired with a 3.5-megahertz curved array probe on an eZono 4000 system at a 7.5-centimeter depth setting. The video set consisted of twelve human clips recorded from six surgical patients during routine anesthesia and eight clips recorded from four phantom models. An expert categorized seventeen clips as straightforward and three human esophageal clips as difficult due to confounding anatomical artifacts, such as transverse processes. Logistic regression with mixed effects in R version 4.5.1 analyzed learner accuracy, treating video type and difficulty as fixed effects and learner identification as a random intercept. Across all 198 esophageal evaluations, learners identified malposition in 181 instances, achieving an accuracy of 91.4 percent. When depicting esophageal placement, no statistically significant difference in interpretation accuracy emerged between human and phantom clips, yielding a p-value of 0.07. Across the full clip dataset, phantom clips exhibited significantly higher odds of correct interpretation (odds ratio 7.9, 95% confidence interval 2.23 to 50.32, p = 0.006).
Learners also evaluated the recognizability of relevant anatomical findings across three hundred and seventy-eight clip viewings using mixed-effects median regressions implemented in the lqmm package. The overall median recognizability score reached 8 on the eleven-point scale, with an interquartile range of 7 to 10. Recognizability was rated significantly higher in phantom video clips than in human recordings, reaching statistical significance with a p-value of less than 0.001. Phantom sonograms achieved a median score of 10 with an interquartile range of 9 to 10, whereas human sonograms registered a median score of 8 with an interquartile range of 6 to 9. While this pristine acoustic contrast supports early pattern recognition among novice learners, the authors noted that future simulator iterations may require refinement to capture the complex visual artifacts inherent to emergency airway sonography in diverse patient populations.
In contextualizing their findings, the investigators emphasized several structural and pedagogical limitations of the study. The current investigation provides technical and perceptual validation of the prototype rather than empirical evidence of clinical educational efficacy. Because novice evaluation was conducted using pre-recorded video sequences, the study did not measure practical competency in live transducer handling, gain optimization, or real-time image acquisition under emergency conditions. Furthermore, the external visibility of the gelatine block on the mannequin’s anterior neck served as an unintended visual prompt, potentially alerting resuscitation providers to perform airway confirmation and ultrasound checks. The research team also noted that the study did not evaluate skill retention or the transfer of ultrasound competence to clinical practice. Nevertheless, the modular simulator offers an accessible, low-cost training model aligned with global health recommendations from the Lancet Commission on Global Surgery, providing a practical foundation for future educational research comparing airway ultrasound against capnography and auscultation during cardiopulmonary resuscitation.
Subject of Research: Modular adult airway ultrasound simulation for detecting esophageal tube misplacement
Article Title: A novel simulator system for airway ultrasound training to identify oesophageal endotracheal tube malposition
Article References: Bentz, J., Damjanovic, D., Grahl-Römer, C., Dahmer, I., Lebeau, C., & Breitkreutz, R. (2026). A novel simulator system for airway ultrasound training to identify oesophageal endotracheal tube malposition. International Journal of Emergency Medicine, 19(1), Article 302. https://doi.org/10.1186/s12245-026-01412-w
Image Credits: AI Generated
DOI: 10.1186/s12245-026-01412-w
Keywords: airway ultrasound, point-of-care ultrasound, endotracheal intubation, esophageal misplacement, airway management, cardiopulmonary resuscitation, ultrasound phantom, ballistic gelatine, medical simulation, advanced life support, double airway tract sign, capnography, type-one exam, type-two exam, resuscitation mannequin, novice learner training, emergency airway education
News Source: Ophelia Keating. (November 27, 2026). Modular Adult Airway Simulator Enables Reliable Ultrasound Detection of Esophageal Tube Misplacement. Scienmag.